| 1 |
Supplier Profile 01 |
Galvanized light-gauge steel modular panels with insulated sandwich walls |
18–24 m² per room |
30–45 days after approved drawings |
Approximately 30–50 years with corrosion protection and routine maintenance |
U-value calculations and panel datasheets |
Material reaction and fire-resistance reports available by project specification |
High: layouts, openings, finishes, and MEP routing |
Factory inspection, incoming-material checks, dimensional inspection, packing list control |
Commonly 1 year for workmanship; longer structural terms may be negotiated |
91/100 |
| 2 |
Supplier Profile 02 |
Foldable or expandable steel modules for rapid deployment |
15–28 m² per room |
25–40 days after design confirmation |
Approximately 20–40 years, depending on coating system and environment |
Insulation thickness and thermal conductivity data |
Fire-rating documentation normally requires destination-country confirmation |
High: room plans, doors, windows, furniture, and electrical packages |
Prototype approval, weld inspection, folding-mechanism testing, pre-shipment checks |
Typically 12 months for manufacturing defects |
89/100 |
| 3 |
Supplier Profile 03 |
Container-style modular steel units with factory-installed interiors |
14–30 m² per room |
35–55 days after final drawings |
Approximately 30–50 years when protected against moisture and corrosion |
Wall, roof, and floor assembly specifications |
Fire, smoke, and egress compliance must be checked against local building codes |
Medium to high: standard modules with selected design options |
Welding records, coating checks, water-ingress inspection, electrical testing |
Usually 1 year for supplied components and workmanship |
87/100 |
| 4 |
Supplier Profile 04 |
Cold-formed steel frame with calcium-silicate or fiber-cement boards |
16–26 m² per room |
40–60 days after engineering approval |
Approximately 40–60 years with appropriate maintenance |
Thermal-bridge details and insulation specifications |
Non-combustible board options and tested wall assemblies may be offered |
High: façade, partition, ceiling, and interior finish options |
Material traceability, fastener checks, board installation inspection, assembly tolerances |
Commonly 12–24 months depending on contract scope |
86/100 |
| 5 |
Supplier Profile 05 |
Prefabricated steel frame with EPS or rock-wool sandwich panels |
12–24 m² per room |
25–45 days for standard configurations |
Approximately 25–40 years, subject to panel and coating quality |
Panel density, thickness, and conductivity data |
Rock-wool alternatives can support higher fire-performance requirements |
Medium: standard plans with configurable doors, windows, and finishes |
Panel thickness checks, steel-gauge verification, assembly inspection, packaging control |
Typically 1 year for workmanship and supplied materials |
84/100 |
| 6 |
Supplier Profile 06 |
Flat-pack steel frame kits with separately sourced local infill materials |
15–32 m² per room |
20–35 days for frame packages |
Approximately 30–50 years for protected structural steel |
Frame calculations; infill performance depends on local materials |
Local contractor and authority approvals are usually required for completed walls |
High: flexible room planning and locally selected finishes |
Frame dimensional checks, bolt and connection inspection, installation manuals |
Usually limited to the supplied frame and connection components |
82/100 |
| 7 |
Supplier Profile 07 |
Lightweight modular units using aluminum or galvanized steel subframes |
12–22 m² per room |
35–50 days after engineering sign-off |
Approximately 25–40 years, depending on frame material and climate |
Insulation and condensation-control specifications |
Fire performance varies significantly by wall, ceiling, and interior finish selection |
Medium to high: compact layouts and interior package options |
Frame alignment checks, moisture protection inspection, electrical continuity testing |
Commonly 12 months for manufacturing and installation defects |
80/100 |
| 8 |
Supplier Profile 08 |
Budget-oriented panelized accommodation with standardized room modules |
10–20 m² per room |
20–35 days for standard models |
Approximately 20–35 years with regular maintenance |
Basic insulation thickness and material data |
Additional fire upgrades and local certification may be necessary |
Medium: limited plan and finish variations |
Standard production inspection and visual quality checks |
Often 12 months for manufacturing defects |
77/100 |
| 9 |
Supplier Profile 09 |
Hybrid modular system combining steel frames with prefabricated concrete or board elements |
18–35 m² per room |
50–75 days due to heavier components |
Approximately 40–60 years when correctly engineered and maintained |
Detailed envelope calculations generally available |
Concrete and mineral-based assemblies may provide strong fire performance when tested |
Medium: robust standard layouts with selected architectural adaptations |
Concrete strength records, reinforcement checks, dimensional surveys, delivery inspections |
Typically 12–24 months, subject to component and installation scope |
76/100 |
| 10 |
Supplier Profile 10 |
Portable flat-pack cabins for temporary or seasonal dormitory use |
9–18 m² per room |
15–30 days for standard units |
Approximately 15–30 years, depending on relocation frequency and exposure |
Basic thermal data; project-specific calculations recommended |
Emergency lighting, alarms, exits, and fire ratings require local review |
Low to medium: primarily standard configurations |
Pre-dispatch inspection, packing verification, assembly instructions, basic functional testing |
Commonly 6–12 months for supplied components |
73/100 |